IBDFU9 ;ALB/CJM - ENCOUNTER FORM - post-selection action for package interface file, screen for data qualifiers;OCT 18,1993
;;3.0;AUTOMATED INFO COLLECTION SYS;;APR 24, 1997
;
ASK ;post-slection action for package interface
Q:'$D(VALMEVL) ; only ask if in listman
Q:DIC["358.6"
N LINE,DA,ANS,TYPE
S DA=+Y
I $G(DA),$D(^IBE(357.6,DA,1)) D
.S TYPE=$P($G(^IBE(357.6,DA,0)),"^",6)
.;
.; -- see if we can find a marker and quit if in fileman
.;
.; -- in the case of reports, the post-selection action is not executed
.; until after the report is created in the setup, so it's not useful
.Q:TYPE=4
.;
.S TYPE=$S(TYPE=1:"type of data",TYPE=2:"type of data",TYPE=3:"type of data",TYPE=4:"report",1:"package interface")
.S LINE=0 W ! F S LINE=$O(^IBE(357.6,DA,1,LINE)) Q:'LINE W !,$G(^IBE(357.6,DA,1,LINE,0))
.W !!,"Are you sure this is the right "_TYPE_"?: "
.R ANS:DTIME
.I '$T S Y=-1 Q
.I ANS["?" W !!,"Enter Y for YES if the data is correct.",!,"Enter N for NO if the data is not correct." D
..W !!,"Are you sure this is the right "_TYPE_"?: "
..R ANS:DTIME
.I (ANS["^")!(ANS["?")!(ANS="")!("Yy"'[$E(ANS,1)) S Y=-1
Q
;
DQGOOD(PI,QLFR) ;screen for data modifiers
;
N NODE
Q:'$G(PI) 0
Q:'$G(QLFR) 0
S NODE=$G(^IBE(357.6,PI,0))
;
;for selection interfaces, the list of data qualifiers is kept with the input interface
I $P(NODE,"^",6)=3 S PI=$P(NODE,"^",13)
Q:'PI 0
Q $D(^IBE(357.6,PI,13,"B",QLFR_";IBD(357.98,"))
;
DTGOOD(PI,TYPE) ;screen for datatypes
;
N NODE
Q:'$G(PI) 0
Q:'$G(TYPE) 0
S NODE=$G(^IBE(357.6,PI,0))
;
;for selection interfaces, the list of data qualifiers is kept with the input interface
I $P(NODE,"^",6)=3 S PI=$P(NODE,"^",13)
Q:'PI 0
Q $D(^IBE(357.6,PI,13,"B",TYPE_";IBE(359.1,"))
IBDFU9 ;ALB/CJM - ENCOUNTER FORM - post-selection action for package interface file, screen for data qualifiers;OCT 18,1993
+1 ;;3.0;AUTOMATED INFO COLLECTION SYS;;APR 24, 1997
+2 ;
ASK ;post-slection action for package interface
+1 ; only ask if in listman
IF '$DATA(VALMEVL)
QUIT
+2 IF DIC["358.6"
QUIT
+3 NEW LINE,DA,ANS,TYPE
+4 SET DA=+Y
+5 IF $GET(DA)
IF $DATA(^IBE(357.6,DA,1))
Begin DoDot:1
+6 SET TYPE=$PIECE($GET(^IBE(357.6,DA,0)),"^",6)
+7 ;
+8 ; -- see if we can find a marker and quit if in fileman
+9 ;
+10 ; -- in the case of reports, the post-selection action is not executed
+11 ; until after the report is created in the setup, so it's not useful
+12 IF TYPE=4
QUIT
+13 ;
+14 SET TYPE=$SELECT(TYPE=1:"type of data",TYPE=2:"type of data",TYPE=3:"type of data",TYPE=4:"report",1:"package interface")
+15 SET LINE=0
WRITE !
FOR
SET LINE=$ORDER(^IBE(357.6,DA,1,LINE))
IF 'LINE
QUIT
WRITE !,$GET(^IBE(357.6,DA,1,LINE,0))
+16 WRITE !!,"Are you sure this is the right "_TYPE_"?: "
+17 READ ANS:DTIME
+18 IF '$TEST
SET Y=-1
QUIT
+19 IF ANS["?"
WRITE !!,"Enter Y for YES if the data is correct.",!,"Enter N for NO if the data is not correct."
Begin DoDot:2
+20 WRITE !!,"Are you sure this is the right "_TYPE_"?: "
+21 READ ANS:DTIME
End DoDot:2
+22 IF (ANS["^")!(ANS["?")!(ANS="")!("Yy"'[$EXTRACT(ANS,1))
SET Y=-1
End DoDot:1
+23 QUIT
+24 ;
DQGOOD(PI,QLFR) ;screen for data modifiers
+1 ;
+2 NEW NODE
+3 IF '$GET(PI)
QUIT 0
+4 IF '$GET(QLFR)
QUIT 0
+5 SET NODE=$GET(^IBE(357.6,PI,0))
+6 ;
+7 ;for selection interfaces, the list of data qualifiers is kept with the input interface
+8 IF $PIECE(NODE,"^",6)=3
SET PI=$PIECE(NODE,"^",13)
+9 IF 'PI
QUIT 0
+10 QUIT $DATA(^IBE(357.6,PI,13,"B",QLFR_";IBD(357.98,"))
+11 ;
DTGOOD(PI,TYPE) ;screen for datatypes
+1 ;
+2 NEW NODE
+3 IF '$GET(PI)
QUIT 0
+4 IF '$GET(TYPE)
QUIT 0
+5 SET NODE=$GET(^IBE(357.6,PI,0))
+6 ;
+7 ;for selection interfaces, the list of data qualifiers is kept with the input interface
+8 IF $PIECE(NODE,"^",6)=3
SET PI=$PIECE(NODE,"^",13)
+9 IF 'PI
QUIT 0
+10 QUIT $DATA(^IBE(357.6,PI,13,"B",TYPE_";IBE(359.1,"))