PSBOBLU ;BIRMINGHAM/TTH-BUILD CONTROL CODES ;Mar 2004
;;3.0;BAR CODE MED ADMIN;**2**;Mar 2004;Build 22
;;Per VHA Directive 2004-038 (or future revisions regarding same), this routine should not be modified.
;
; Reference/IA
; ^%ZIS(2/3435
; ^%ZIS(2/3884
;
N AB,ANS,CODE,NAME,PSBCHO,PSBCODE,PSBTYPE,X,Y
;
W !," ***Important Note***"
W !,"Before you execute the automatic control code update function, create a ",!,"new terminal type entry in your TERMINAL TYPE file (#3.2) to store the "
W !,"new barcode printer control codes. The new terminal type entry needs to ",!,"be connected to the barcode printer device by inserting the new terminal "
W !,"type entry name into the SUBTYPE field (#3) for the barcode printer entry ",!,"in your DEVICE file (#3.5). ",!
W !,"This option will allow you to automatically copy the BCMA pre-formatted",!,"control codes for the Zebra barcode printer or Intermec barcode printer"
W !,"to a device. Please select the appropriate BCMA pre-formatted control",!,"codes and then select the appropriate device.",!
;
K DIR,DA,PSBCHO
S DIR(0)="SX^1:Zebra Control Codes;2:Intermec Control Codes"
S DIR("A")="Select 1 or 2"
D ^DIR S PSBCHO=Y
I $G(DIRUT) D END Q
I PSBCHO["^" D END Q
;
D IO
;
END ;Clean Up Routine Variables
K %ZIS,DA,DIC,DIE,DIR,DIROUT,DIRUT,DR,DTOUT,DUOUT,POP,X,Y
Q
;
;Select Device ;
IO S %ZIS("B")="" D ^%ZIS Q:POP
Q:$G(DIRUT)
;
;Check system
W !!,"Checking system status....",!
I '$G(IOST(0)) W "No Terminal Type available." Q
I '$D(DUZ(0)) W "No DUZ defined." Q
I DUZ(0)'="@" W "FileMan access must be @." Q
;
;Check for existing control entry in Terminal Type file.
I $D(^%ZIS(2,IOST(0),55,"B","SB")) W !!,"***Warning*** BCMA CONTROL CODES already defined for this device.",!
W !,"Are you sure that you want to copy the ",!,"BCMA CONTROL CODES to device: ",ION,!
;
WHAT ; Yes to continue No to Quit
K DIR,ANS
S DIR(0)="Y^O",DIR("B")="NO",DIR("T")=20
D ^DIR S ANS=Y
Q:ANS["^"
Q:ANS'=1
W " Copying Control Codes...",!
;
I PSBCHO=1 D ZEBCC
I PSBCHO=2 D INTMECC
W !,"Done..."
Q
;
ZEBCC ;Zebral Barcode Printer Character Control Code auto install
; Use $SELECT function to set proper barcode printer control code variable "CODE"
;
I '$D(^%ZIS(2,IOST(0),55,"B","SL")) S AB="SL",NAME="Start Label",CODE="W !,""^XA"",!,""^LH0,0^FS""" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","EL")) S AB="EL",NAME="End Label",CODE="W !,""^XZ""" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","ST")) S AB="ST",NAME="Start Text",CODE="W !,""^FO""_PSBTYPE_""^A0N,30,20^CI13^FR^FD""_TEXT_""^FS""" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","SB")) S AB="SB",NAME="Start Barcode" D D FILE
.S CODE="S PSBTYPE=$S(PSBSYM=""I25"":""B2N"",PSBSYM=""128"":""BCN"",1:""B3N"")"
.S CODE=CODE_" S:PSBSYM="""" PSBBAR=""NO-CODE"" W !,""^BY2,3.0,80^FO20,100^""_PSBTYPE_"",N,80,Y,N^FR^FD""_PSBBAR_""^FS"""
I '$D(^%ZIS(2,IOST(0),55,"B","STF")) S AB="STF",NAME="Start Text Field" D D FILE
.S CODE="S PSBTYPE=$S(PSBTLE=""PSBDRUG"":""20,25"",PSBTLE=""PSBDOSE"":""20,60"",PSBTLE=""PSBNAME"":""350,60"",PSBTLE=""PSBWARD"":""350,90"",PSBTLE=""PSBLOT"":""350,120"","
.S CODE=CODE_"PSBTLE=""PSBEXP"":""350,150"",PSBTLE=""PSBMFG"":""500,150"",PSBTLE=""PSBFCB"":""350,180"",1:""0,0"")"
Q
;
INTMECC ;Intermec Barcode Printer Character Control Code auto install
I '$D(^%ZIS(2,IOST(0),55,"B","SL")) S AB="SL",NAME="Start Label",CODE="W ""<STX>R;<EXT>"",!,""<STX><ESC>E2<EXT>"",!" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","EL")) S AB="EL",NAME="End Label",CODE="W ""<STX><ETB><ETX>"",!" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","SB")) S AB="SB",NAME="Start Barcode",CODE="W ""<STX>""_TEXT_""<ETX>"",!" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","ST")) S AB="ST",NAME="Start Text",CODE="W ""<STX>""_TEXT_""<CR><ETX>"",!" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","EBF")) S AB="EBF",NAME="End Barcode",CODE="W ""<STX>H8;o50,40;f3;c0;h1;w1;d0,80;<ETX>"",!" D FILE
I '$D(^%ZIS(2,IOST(0),55,"B","FI")) S AB="FI",NAME="Format Initialization",CODE="W ""<STX><ESC>C<ETX>"",!,""<STX><ESC>P<ETX>"",!,""<STX>E2;F2<ESC><ETX>"",!" D FILE
;
I '$D(^%ZIS(2,IOST(0),55,"B","SBF")) S AB="SBF",NAME="Start Barcode Field" D D FILE
.S CODE="S PSBTYPE=$S(PSBSYM=""I25"":""c2,0"",PSBSYM=""128"":""c6,0"",1:""c0,0"")"
.S CODE=CODE_" W ""<STX>B8;o85,40;f3;""_PSBTYPE_"";h50;w1;i1;do,25;p@;<ETX>"",!,""<STX>I8;h1;w1;<ETX>"",!"
;
I '$D(^%ZIS(2,IOST(0),55,"B","FI1")) S AB="FI1",NAME="Format Initialization 1" D D FILE
.S CODE="W ""<STX>H7;o30,260;f3;c0;h1;w1;d0,80;<ETX>"",!,""<STX>H6;o50,440;f3;c0;h1;w1;d0,20;<ETX>"",!,"
.S CODE=CODE_"""<STX>H5;o50,260;f3;c0;h1;w1;d0,20;<ETX>"",!,""<STX>H4;o70,260;f3;c0;h1;w1;d0,35;<ETX>"",!"
;
I '$D(^%ZIS(2,IOST(0),55,"B","FI2")) S AB="FI2",NAME="Format Initialization 2" D D FILE
.S CODE="W ""<STX>H3;o90,260;f3;c0;h1;w1;d0,35;<ETX>"",!,""<STX>H2;o110,260;f3;c0;h1;w1;d0,35;<ETX>"",!,"
.S CODE=CODE_"""<STX>H1;o110,40;f3;c0;h1;w1;d0,27;<ETX>"",!,""<STX>H0;o130,40;f3;c0;h1;w1;d0,60;<ETX>"",!"
Q
;
FILE ;Set local array for Intermec Barcode Printer Default Settings
;
K DD,DIC,DIE,DO
S DIC(0)="L",DA(1)=IOST(0),X=AB,DIC="^%ZIS(2,"_DA(1)_",55," D FILE^DICN K DD,DO
S DIE=DIC,DA=+Y,DA(1)=IOST(0)
S DR=".01////"_AB_";1////"_NAME_";2////^S X=CODE" D ^DIE
Q
PSBOBLU ;BIRMINGHAM/TTH-BUILD CONTROL CODES ;Mar 2004
+1 ;;3.0;BAR CODE MED ADMIN;**2**;Mar 2004;Build 22
+2 ;;Per VHA Directive 2004-038 (or future revisions regarding same), this routine should not be modified.
+3 ;
+4 ; Reference/IA
+5 ; ^%ZIS(2/3435
+6 ; ^%ZIS(2/3884
+7 ;
+8 NEW AB,ANS,CODE,NAME,PSBCHO,PSBCODE,PSBTYPE,X,Y
+9 ;
+10 WRITE !," ***Important Note***"
+11 WRITE !,"Before you execute the automatic control code update function, create a ",!,"new terminal type entry in your TERMINAL TYPE file (#3.2) to store the "
+12 WRITE !,"new barcode printer control codes. The new terminal type entry needs to ",!,"be connected to the barcode printer device by inserting the new terminal "
+13 WRITE !,"type entry name into the SUBTYPE field (#3) for the barcode printer entry ",!,"in your DEVICE file (#3.5). ",!
+14 WRITE !,"This option will allow you to automatically copy the BCMA pre-formatted",!,"control codes for the Zebra barcode printer or Intermec barcode printer"
+15 WRITE !,"to a device. Please select the appropriate BCMA pre-formatted control",!,"codes and then select the appropriate device.",!
+16 ;
+17 KILL DIR,DA,PSBCHO
+18 SET DIR(0)="SX^1:Zebra Control Codes;2:Intermec Control Codes"
+19 SET DIR("A")="Select 1 or 2"
+20 DO ^DIR
SET PSBCHO=Y
+21 IF $GET(DIRUT)
DO END
QUIT
+22 IF PSBCHO["^"
DO END
QUIT
+23 ;
+24 DO IO
+25 ;
END ;Clean Up Routine Variables
+1 KILL %ZIS,DA,DIC,DIE,DIR,DIROUT,DIRUT,DR,DTOUT,DUOUT,POP,X,Y
+2 QUIT
+3 ;
+4 ;Select Device ;
IO SET %ZIS("B")=""
DO ^%ZIS
IF POP
QUIT
+1 IF $GET(DIRUT)
QUIT
+2 ;
+3 ;Check system
+4 WRITE !!,"Checking system status....",!
+5 IF '$GET(IOST(0))
WRITE "No Terminal Type available."
QUIT
+6 IF '$DATA(DUZ(0))
WRITE "No DUZ defined."
QUIT
+7 IF DUZ(0)'="@"
WRITE "FileMan access must be @."
QUIT
+8 ;
+9 ;Check for existing control entry in Terminal Type file.
+10 IF $DATA(^%ZIS(2,IOST(0),55,"B","SB"))
WRITE !!,"***Warning*** BCMA CONTROL CODES already defined for this device.",!
+11 WRITE !,"Are you sure that you want to copy the ",!,"BCMA CONTROL CODES to device: ",ION,!
+12 ;
WHAT ; Yes to continue No to Quit
+1 KILL DIR,ANS
+2 SET DIR(0)="Y^O"
SET DIR("B")="NO"
SET DIR("T")=20
+3 DO ^DIR
SET ANS=Y
+4 IF ANS["^"
QUIT
+5 IF ANS'=1
QUIT
+6 WRITE " Copying Control Codes...",!
+7 ;
+8 IF PSBCHO=1
DO ZEBCC
+9 IF PSBCHO=2
DO INTMECC
+10 WRITE !,"Done..."
+11 QUIT
+12 ;
ZEBCC ;Zebral Barcode Printer Character Control Code auto install
+1 ; Use $SELECT function to set proper barcode printer control code variable "CODE"
+2 ;
+3 IF '$DATA(^%ZIS(2,IOST(0),55,"B","SL"))
SET AB="SL"
SET NAME="Start Label"
SET CODE="W !,""^XA"",!,""^LH0,0^FS"""
DO FILE
+4 IF '$DATA(^%ZIS(2,IOST(0),55,"B","EL"))
SET AB="EL"
SET NAME="End Label"
SET CODE="W !,""^XZ"""
DO FILE
+5 IF '$DATA(^%ZIS(2,IOST(0),55,"B","ST"))
SET AB="ST"
SET NAME="Start Text"
SET CODE="W !,""^FO""_PSBTYPE_""^A0N,30,20^CI13^FR^FD""_TEXT_""^FS"""
DO FILE
+6 IF '$DATA(^%ZIS(2,IOST(0),55,"B","SB"))
SET AB="SB"
SET NAME="Start Barcode"
Begin DoDot:1
+7 SET CODE="S PSBTYPE=$S(PSBSYM=""I25"":""B2N"",PSBSYM=""128"":""BCN"",1:""B3N"")"
+8 SET CODE=CODE_" S:PSBSYM="""" PSBBAR=""NO-CODE"" W !,""^BY2,3.0,80^FO20,100^""_PSBTYPE_"",N,80,Y,N^FR^FD""_PSBBAR_""^FS"""
End DoDot:1
DO FILE
+9 IF '$DATA(^%ZIS(2,IOST(0),55,"B","STF"))
SET AB="STF"
SET NAME="Start Text Field"
Begin DoDot:1
+10 SET CODE="S PSBTYPE=$S(PSBTLE=""PSBDRUG"":""20,25"",PSBTLE=""PSBDOSE"":""20,60"",PSBTLE=""PSBNAME"":""350,60"",PSBTLE=""PSBWARD"":""350,90"",PSBTLE=""PSBLOT"":""350,120"","
+11 SET CODE=CODE_"PSBTLE=""PSBEXP"":""350,150"",PSBTLE=""PSBMFG"":""500,150"",PSBTLE=""PSBFCB"":""350,180"",1:""0,0"")"
End DoDot:1
DO FILE
+12 QUIT
+13 ;
INTMECC ;Intermec Barcode Printer Character Control Code auto install
+1 IF '$DATA(^%ZIS(2,IOST(0),55,"B","SL"))
SET AB="SL"
SET NAME="Start Label"
SET CODE="W ""<STX>R;<EXT>"",!,""<STX><ESC>E2<EXT>"",!"
DO FILE
+2 IF '$DATA(^%ZIS(2,IOST(0),55,"B","EL"))
SET AB="EL"
SET NAME="End Label"
SET CODE="W ""<STX><ETB><ETX>"",!"
DO FILE
+3 IF '$DATA(^%ZIS(2,IOST(0),55,"B","SB"))
SET AB="SB"
SET NAME="Start Barcode"
SET CODE="W ""<STX>""_TEXT_""<ETX>"",!"
DO FILE
+4 IF '$DATA(^%ZIS(2,IOST(0),55,"B","ST"))
SET AB="ST"
SET NAME="Start Text"
SET CODE="W ""<STX>""_TEXT_""<CR><ETX>"",!"
DO FILE
+5 IF '$DATA(^%ZIS(2,IOST(0),55,"B","EBF"))
SET AB="EBF"
SET NAME="End Barcode"
SET CODE="W ""<STX>H8;o50,40;f3;c0;h1;w1;d0,80;<ETX>"",!"
DO FILE
+6 IF '$DATA(^%ZIS(2,IOST(0),55,"B","FI"))
SET AB="FI"
SET NAME="Format Initialization"
SET CODE="W ""<STX><ESC>C<ETX>"",!,""<STX><ESC>P<ETX>"",!,""<STX>E2;F2<ESC><ETX>"",!"
DO FILE
+7 ;
+8 IF '$DATA(^%ZIS(2,IOST(0),55,"B","SBF"))
SET AB="SBF"
SET NAME="Start Barcode Field"
Begin DoDot:1
+9 SET CODE="S PSBTYPE=$S(PSBSYM=""I25"":""c2,0"",PSBSYM=""128"":""c6,0"",1:""c0,0"")"
+10 SET CODE=CODE_" W ""<STX>B8;o85,40;f3;""_PSBTYPE_"";h50;w1;i1;do,25;p@;<ETX>"",!,""<STX>I8;h1;w1;<ETX>"",!"
End DoDot:1
DO FILE
+11 ;
+12 IF '$DATA(^%ZIS(2,IOST(0),55,"B","FI1"))
SET AB="FI1"
SET NAME="Format Initialization 1"
Begin DoDot:1
+13 SET CODE="W ""<STX>H7;o30,260;f3;c0;h1;w1;d0,80;<ETX>"",!,""<STX>H6;o50,440;f3;c0;h1;w1;d0,20;<ETX>"",!,"
+14 SET CODE=CODE_"""<STX>H5;o50,260;f3;c0;h1;w1;d0,20;<ETX>"",!,""<STX>H4;o70,260;f3;c0;h1;w1;d0,35;<ETX>"",!"
End DoDot:1
DO FILE
+15 ;
+16 IF '$DATA(^%ZIS(2,IOST(0),55,"B","FI2"))
SET AB="FI2"
SET NAME="Format Initialization 2"
Begin DoDot:1
+17 SET CODE="W ""<STX>H3;o90,260;f3;c0;h1;w1;d0,35;<ETX>"",!,""<STX>H2;o110,260;f3;c0;h1;w1;d0,35;<ETX>"",!,"
+18 SET CODE=CODE_"""<STX>H1;o110,40;f3;c0;h1;w1;d0,27;<ETX>"",!,""<STX>H0;o130,40;f3;c0;h1;w1;d0,60;<ETX>"",!"
End DoDot:1
DO FILE
+19 QUIT
+20 ;
FILE ;Set local array for Intermec Barcode Printer Default Settings
+1 ;
+2 KILL DD,DIC,DIE,DO
+3 SET DIC(0)="L"
SET DA(1)=IOST(0)
SET X=AB
SET DIC="^%ZIS(2,"_DA(1)_",55,"
DO FILE^DICN
KILL DD,DO
+4 SET DIE=DIC
SET DA=+Y
SET DA(1)=IOST(0)
+5 SET DR=".01////"_AB_";1////"_NAME_";2////^S X=CODE"
DO ^DIE
+6 QUIT