PSXYMSG ;BIR/HTW-Dual Line Error Msg Utility ;[ 02/20/99 5:45 PM ]
;;2.0;CMOP;**17**;11 Apr 97
QRY1 K LOG S LOG(1)="QRY1 QRY message never received for query #"_PSXQRYID Q
QRY2 K LOG S LOG(1)="QRY2 EOT received with no terminator while waiting for QRY message" Q
QRY3 K LOG S LOG(1)="QRY3 EOT received while waiting for QRY message" Q
QRY5 ;K LOG S LOG(1)="QRY5 Unexpected character received: "_$S(X>31:$C(X),1:"")_" ("_X_") while waiting for QRY message" Q
K LOG S LOG(1)="QRY5 Unexpected character received: "_X_"^"_$G(QF) Q
QRY6 K LOG S LOG(1)="QRY6 Timeout Timer D reading QRY message" Q
QRY7 K LOG S LOG(1)="QRY7 QRY message longer than 240 characters" Q
QRY8 K LOG S LOG(1)="QRY8 QRY message did not end with ETX" Q
QRY9 K LOG S LOG(1)="QRY9 QRY was null" Q
QRY10 K LOG S LOG(1)="QRY10 Timeout reading QRY checksum" Q
QRY11 K LOG S LOG(1)="QRY11 QRY checksum contained an invalid hex digit ("_X_")" Q
QRY12 K LOG S LOG(1)="QRY12 QRY checksum does not match" Q
QRY13 K LOG S LOG(1)="QRY13 Message #"_PSXQRYID_" was rejected by OMCS" Q
QRY14 K LOG S LOG(1)="QRY14 ENQ received with no terminator" Q
QRY15 K LOG S LOG(1)="QRY15 MSA message ID did not match PSXQRYID # expected" Q
QRY16 K LOG S LOG(1)="QRY16 Block count greater than 7." Q
QRY17 K LOG S LOG(1)="QRY17 Wrong Block count received." Q
QRY18 K LOG S LOG(1)="QRY18 Maximum retries reached for receiving message." Q
QRY19 K LOG S LOG(1)="QRY19 Maximum Rxs received, query terminated." Q
QRY20 K LOG S LOG(1)="QRY20 No activity on line continuing to monitor." Q
MST1 K LOG S LOG(1)="MST1 ENQ received with no terminator while Bidding for Master status." Q
MST2 K LOG S LOG(1)="MST2 NAK received with no terminator while Bidding for Master status." Q
MST3 K LOG S LOG(1)="MST3 ACK without 0 received while Bidding for Master status." Q
MST4 K LOG S LOG(1)="MST4 Garbage received while Bidding for Master status." Q
MST5 K LOG S LOG(1)="MST5 NAK received while Bidding for Master status." Q
MST6 K LOG S LOG(1)="MST6 No response from CMOP while Bidding for Master status." Q
MST7 K LOG S LOG(1)="MST7 Simultaneous bid for Master status by CMOP and DHCP." Q
MST8 K LOG S LOG(1)="MST8 ACK received with no terminator while Bidding for Master status." Q
MST9 K LOG S LOG(1)="MST9 CMOP won't respond, waiting 45 seconds to try again" Q
PSXYMSG ;BIR/HTW-Dual Line Error Msg Utility ;[ 02/20/99 5:45 PM ]
+1 ;;2.0;CMOP;**17**;11 Apr 97
QRY1 KILL LOG
SET LOG(1)="QRY1 QRY message never received for query #"_PSXQRYID
QUIT
QRY2 KILL LOG
SET LOG(1)="QRY2 EOT received with no terminator while waiting for QRY message"
QUIT
QRY3 KILL LOG
SET LOG(1)="QRY3 EOT received while waiting for QRY message"
QUIT
QRY5 ;K LOG S LOG(1)="QRY5 Unexpected character received: "_$S(X>31:$C(X),1:"")_" ("_X_") while waiting for QRY message" Q
+1 KILL LOG
SET LOG(1)="QRY5 Unexpected character received: "_X_"^"_$GET(QF)
QUIT
QRY6 KILL LOG
SET LOG(1)="QRY6 Timeout Timer D reading QRY message"
QUIT
QRY7 KILL LOG
SET LOG(1)="QRY7 QRY message longer than 240 characters"
QUIT
QRY8 KILL LOG
SET LOG(1)="QRY8 QRY message did not end with ETX"
QUIT
QRY9 KILL LOG
SET LOG(1)="QRY9 QRY was null"
QUIT
QRY10 KILL LOG
SET LOG(1)="QRY10 Timeout reading QRY checksum"
QUIT
QRY11 KILL LOG
SET LOG(1)="QRY11 QRY checksum contained an invalid hex digit ("_X_")"
QUIT
QRY12 KILL LOG
SET LOG(1)="QRY12 QRY checksum does not match"
QUIT
QRY13 KILL LOG
SET LOG(1)="QRY13 Message #"_PSXQRYID_" was rejected by OMCS"
QUIT
QRY14 KILL LOG
SET LOG(1)="QRY14 ENQ received with no terminator"
QUIT
QRY15 KILL LOG
SET LOG(1)="QRY15 MSA message ID did not match PSXQRYID # expected"
QUIT
QRY16 KILL LOG
SET LOG(1)="QRY16 Block count greater than 7."
QUIT
QRY17 KILL LOG
SET LOG(1)="QRY17 Wrong Block count received."
QUIT
QRY18 KILL LOG
SET LOG(1)="QRY18 Maximum retries reached for receiving message."
QUIT
QRY19 KILL LOG
SET LOG(1)="QRY19 Maximum Rxs received, query terminated."
QUIT
QRY20 KILL LOG
SET LOG(1)="QRY20 No activity on line continuing to monitor."
QUIT
MST1 KILL LOG
SET LOG(1)="MST1 ENQ received with no terminator while Bidding for Master status."
QUIT
MST2 KILL LOG
SET LOG(1)="MST2 NAK received with no terminator while Bidding for Master status."
QUIT
MST3 KILL LOG
SET LOG(1)="MST3 ACK without 0 received while Bidding for Master status."
QUIT
MST4 KILL LOG
SET LOG(1)="MST4 Garbage received while Bidding for Master status."
QUIT
MST5 KILL LOG
SET LOG(1)="MST5 NAK received while Bidding for Master status."
QUIT
MST6 KILL LOG
SET LOG(1)="MST6 No response from CMOP while Bidding for Master status."
QUIT
MST7 KILL LOG
SET LOG(1)="MST7 Simultaneous bid for Master status by CMOP and DHCP."
QUIT
MST8 KILL LOG
SET LOG(1)="MST8 ACK received with no terminator while Bidding for Master status."
QUIT
MST9 KILL LOG
SET LOG(1)="MST9 CMOP won't respond, waiting 45 seconds to try again"
QUIT