SCMCHL ;BP/DJB - PCMM HL7 Main Calling Point ; 16 Dec 2002 11:14 AM
;;5.3;Scheduling;**177,204,224,272,367,1015**;AUG 13, 1993;Build 21
;
;Reference routine: SCDXMSG
MAIN(MODE,XMITARRY,VARPTR,WORK) ;Main entry point to generate Primary Care HL7
;messages to NPCD in Austin. Loop thru PCMM HL7 EVENT file (#404.48)
;and generate HL7 message for each appropriate event.
;
;Input:
; MODE - Mode of operation.
; 1: Generate mode - Generate HL7 messages. (Default).
; 2: Review mode - HL7 segments will be built in array
; XMITARRY and may be reviewed. HL7
; messages WILL NOT be generated, and
; processed events will not be
; removed from the transmit xref in
; PCMM HL7 EVENT file.
; XMITARRY - Array to store HL7 segments (full global ref).
; Default=^TMP("PCMM","HL7",$J)
; VARPTR - For testing purposes, you may pass in an EVENT POINTER
; value. This value will be used rather than $ORDERing
; thru "AACXMIT" xref in PCMM HL7 EVENT file.
; Examples:
; "2290;SCPT(404.43," (Patient Team Position Assign)
; "725;SCTM(404.52," (Position Assign History)
; "1;SCTM(404.53," (Preceptor Assign History)
; Work Optional if present
;Output: None
;
;Prevent multiple runs processing at the same time.
I $G(VARPTR)'="",$D(^XTMP("SCMCHL")) D Q
.W !,"HL7 Transmission in progress, no testing allowed!",!
I $D(^XTMP("SCMCHL")) D Q
.W !,"HL7 Transmission in progress, please try again later.",!
S ^XTMP("SCMCHL",0)=DT_"^"_DT
;
NEW ERRCNT,IEN,MSG,MSGCNT,RESULT
NEW SCEVIEN,SCFAC
NEW HL,HLECH,HLEID,HLFS,HLQ,HLP,XMITERR
;
;Initialize variables - set global locations
S:$G(MODE)'=2 MODE=1 ;Default mode = "Generate"
S:$G(XMITARRY)="" XMITARRY="^TMP(""PCMM"",""HL7"","_$J_")" ;Segments
S XMITERR="^TMP(""PCMM"",""ERR"","_$J_")" ;Errors
S MSGCNT=0
;
;Get pointer to sending event
S HLEID=$$HLEID()
I 'HLEID D Q
. S MSG="Unable to initialize HL7 variables - protocol not found"
. D ERRBULL^SCMCHLM(MSG)
;
;Initialize HL7 variables
D INIT^HLFNC2(HLEID,.HL)
I $O(HL(""))="" D Q
. D ERRBULL^SCMCHLM($P(HL,"^",2))
;
;Get faciltiy number
S SCFAC=+$P($$SITE^VASITE(),"^",3)
;
;User passed in an EVENT POINTER value
I $G(VARPTR)]"" D MANUAL Q
;
LOOP ;Loop thru EVENT POINTER xref and send message for each unique one.
;alb/rpm Patch 224
;The SCLIMIT counter allows sites to limit the number of HL7 messages
;processed at any one time. The next EVENT POINTER in the queue will
;not be processed if SCLIMIT is exceeded. SCLIMIT is not an absolute
;limit, since a single EVENT POINTER can generate multiple HL7
;messages.
;Sites can modify SCLIMIT by editing the HL7 TRANSMIT LIMIT field of
;the PCMM PARAMETER file.
;
NEW SCLIMIT,WORK,VARPTR
S SCLIMIT=$P($G(^SCTM(404.44,1,1)),U,5) ;Limit # of msgs processed
S:'SCLIMIT SCLIMIT=2500 ;Default to 2500 msgs
S VARPTR=""
F S VARPTR=$O(^SCPT(404.48,"AACXMIT",VARPTR)) Q:VARPTR=""!(SCLIMIT<1) D
. KILL @XMITARRY ;Initialize array
. ;
. ;Preserve the Event IEN. Used to process a deletion.
. F SCEVIEN=0:0 S SCEVIEN=$O(^SCPT(404.48,"AACXMIT",VARPTR,SCEVIEN)) Q:'SCEVIEN D
.. ;
.. ;Build segment array
.. K SCFUT
.. S WORK=+$P($G(^SCPT(404.48,SCEVIEN,0)),U,8)
.. I WORK N HLEID S HLEID=$$HLEIDW() S RESULT=$$BUILD^SCMCHLP(VARPTR,.HL,.XMITARRY,SCEVIEN)
.. I 'WORK S RESULT=$$BUILD^SCMCHLB(VARPTR,.HL,.XMITARRY)
.. I +RESULT<0 D Q ;Error occurred when building segment array
.. . S @XMITERR@(VARPTR)=$P(RESULT,"^",2)
.. ;
.. ;If in Review mode, display info and Quit.
.. I MODE=2 D Q ;
.. . W !,VARPTR_" "_$S('$D(@XMITARRY):"No ",1:"")_"Data Found"
.. ;
.. ;If no segments built, turn off transmission flag and Quit.
.. I '$D(@XMITARRY) D:'$G(SCFUT) FLAG(VARPTR,SCEVIEN) Q
.. ;
.. ;Generate message.
.. ;
.. Q:'$$GENERATE^SCMCHLG() ;^SCMCHLG Increments MSGCNT
.. D:'$G(SCFUT) FLAG(VARPTR,SCEVIEN) ;Turn off transmission flag
.. K @XMITARRY ;clean up variables
. ;
. Q
;
I '$D(ZTQUEUED) W !,MSGCNT," messages sent."
;
;Send completion bulletin and clean up arrays.
I MODE=1 D ;Don't do this if in DISPLAY mode.
. S ERRCNT=$$COUNT^SCMCHLS(XMITERR)
. D CMPLBULL^SCMCHLM(MSGCNT,ERRCNT,XMITERR)
. KILL @XMITARRY,@XMITERR
. K ^XTMP("SCMCHL")
;
Q:SCLIMIT<1
;
;alb/rpm;Patch 224;Transmit "M"arked messages from Transmission Log
D EN^SCMCHLRR(.SCLIMIT)
Q:SCLIMIT<1
;
;alb/rpm;Patch224;Transmit messages with overdue ACKnowledgment
D AUTO^SCMCHLRR(.SCLIMIT)
Q
;
MANUAL ;User passed in a specific variable pointer value. This value will
;be used rather than $ORDERing thru "AACXMIT" xref.
;
NEW SCMANUAL
S SCMANUAL=1 ;Indicates variable pointer was manually entered.
; A delete cannot be processed.
;
;Initialize array
KILL @XMITARRY
;
;Build segment array
I $G(WORK) N HLEID S HLEID=$$HLEIDW() S RESULT=$$BUILD^SCMCHLP(VARPTR,.HL,.XMITARRY)
I '$G(WORK) S RESULT=$$BUILD^SCMCHLB(VARPTR,.HL,.XMITARRY)
I +RESULT<0 D Q ;Error occurred when building segment array
. S @XMITERR@(VARPTR)=$P(RESULT,"^",2)
W !,VARPTR_" "_$S('$D(@XMITARRY):"No ",1:"")_"Data Found",!
;
;Generate message - FOR TESTING PURPOSES ONLY!
S RESULT=$$GENERATE^SCMCHLG()
K ^XTMP("SCMCHL")
Q
;
FLAG(VARPTR,SCEVIEN) ;Turn off transmission flag. This removes event from "AACXMIT"
;xref in PCMM HL7 EVENT file.
;Input:
; VARPTR - Internal value of EVENT POINTER field
;
Q:$G(VARPTR)']""
I $G(SCEVIEN) D TRANSMIT^SCMCHLE(SCEVIEN,0) Q
NEW IEN
S IEN=0
F S IEN=$O(^SCPT(404.48,"AACXMIT",VARPTR,IEN)) Q:'IEN D ;
. D TRANSMIT^SCMCHLE(IEN,0)
Q
;
HLEIDW() ;Return workload sending event
Q +$O(^ORD(101,"B","SCMC SEND SERVER WORKLOAD",0))
HLEID() ;Return pointer to sending event
I $G(WORK) Q $$HLEIDW()
Q +$O(^ORD(101,"B","PCMM SEND SERVER FOR ADT-A08",0))
Q
SCMCHL ;BP/DJB - PCMM HL7 Main Calling Point ; 16 Dec 2002 11:14 AM
+1 ;;5.3;Scheduling;**177,204,224,272,367,1015**;AUG 13, 1993;Build 21
+2 ;
+3 ;Reference routine: SCDXMSG
MAIN(MODE,XMITARRY,VARPTR,WORK) ;Main entry point to generate Primary Care HL7
+1 ;messages to NPCD in Austin. Loop thru PCMM HL7 EVENT file (#404.48)
+2 ;and generate HL7 message for each appropriate event.
+3 ;
+4 ;Input:
+5 ; MODE - Mode of operation.
+6 ; 1: Generate mode - Generate HL7 messages. (Default).
+7 ; 2: Review mode - HL7 segments will be built in array
+8 ; XMITARRY and may be reviewed. HL7
+9 ; messages WILL NOT be generated, and
+10 ; processed events will not be
+11 ; removed from the transmit xref in
+12 ; PCMM HL7 EVENT file.
+13 ; XMITARRY - Array to store HL7 segments (full global ref).
+14 ; Default=^TMP("PCMM","HL7",$J)
+15 ; VARPTR - For testing purposes, you may pass in an EVENT POINTER
+16 ; value. This value will be used rather than $ORDERing
+17 ; thru "AACXMIT" xref in PCMM HL7 EVENT file.
+18 ; Examples:
+19 ; "2290;SCPT(404.43," (Patient Team Position Assign)
+20 ; "725;SCTM(404.52," (Position Assign History)
+21 ; "1;SCTM(404.53," (Preceptor Assign History)
+22 ; Work Optional if present
+23 ;Output: None
+24 ;
+25 ;Prevent multiple runs processing at the same time.
+26 IF $GET(VARPTR)'=""
IF $DATA(^XTMP("SCMCHL"))
Begin DoDot:1
+27 WRITE !,"HL7 Transmission in progress, no testing allowed!",!
End DoDot:1
QUIT
+28 IF $DATA(^XTMP("SCMCHL"))
Begin DoDot:1
+29 WRITE !,"HL7 Transmission in progress, please try again later.",!
End DoDot:1
QUIT
+30 SET ^XTMP("SCMCHL",0)=DT_"^"_DT
+31 ;
+32 NEW ERRCNT,IEN,MSG,MSGCNT,RESULT
+33 NEW SCEVIEN,SCFAC
+34 NEW HL,HLECH,HLEID,HLFS,HLQ,HLP,XMITERR
+35 ;
+36 ;Initialize variables - set global locations
+37 ;Default mode = "Generate"
IF $GET(MODE)'=2
SET MODE=1
+38 ;Segments
IF $GET(XMITARRY)=""
SET XMITARRY="^TMP(""PCMM"",""HL7"","_$JOB_")"
+39 ;Errors
SET XMITERR="^TMP(""PCMM"",""ERR"","_$JOB_")"
+40 SET MSGCNT=0
+41 ;
+42 ;Get pointer to sending event
+43 SET HLEID=$$HLEID()
+44 IF 'HLEID
Begin DoDot:1
+45 SET MSG="Unable to initialize HL7 variables - protocol not found"
+46 DO ERRBULL^SCMCHLM(MSG)
End DoDot:1
QUIT
+47 ;
+48 ;Initialize HL7 variables
+49 DO INIT^HLFNC2(HLEID,.HL)
+50 IF $ORDER(HL(""))=""
Begin DoDot:1
+51 DO ERRBULL^SCMCHLM($PIECE(HL,"^",2))
End DoDot:1
QUIT
+52 ;
+53 ;Get faciltiy number
+54 SET SCFAC=+$PIECE($$SITE^VASITE(),"^",3)
+55 ;
+56 ;User passed in an EVENT POINTER value
+57 IF $GET(VARPTR)]""
DO MANUAL
QUIT
+58 ;
LOOP ;Loop thru EVENT POINTER xref and send message for each unique one.
+1 ;alb/rpm Patch 224
+2 ;The SCLIMIT counter allows sites to limit the number of HL7 messages
+3 ;processed at any one time. The next EVENT POINTER in the queue will
+4 ;not be processed if SCLIMIT is exceeded. SCLIMIT is not an absolute
+5 ;limit, since a single EVENT POINTER can generate multiple HL7
+6 ;messages.
+7 ;Sites can modify SCLIMIT by editing the HL7 TRANSMIT LIMIT field of
+8 ;the PCMM PARAMETER file.
+9 ;
+10 NEW SCLIMIT,WORK,VARPTR
+11 ;Limit # of msgs processed
SET SCLIMIT=$PIECE($GET(^SCTM(404.44,1,1)),U,5)
+12 ;Default to 2500 msgs
IF 'SCLIMIT
SET SCLIMIT=2500
+13 SET VARPTR=""
+14 FOR
SET VARPTR=$ORDER(^SCPT(404.48,"AACXMIT",VARPTR))
IF VARPTR=""!(SCLIMIT<1)
QUIT
Begin DoDot:1
+15 ;Initialize array
KILL @XMITARRY
+16 ;
+17 ;Preserve the Event IEN. Used to process a deletion.
+18 FOR SCEVIEN=0:0
SET SCEVIEN=$ORDER(^SCPT(404.48,"AACXMIT",VARPTR,SCEVIEN))
IF 'SCEVIEN
QUIT
Begin DoDot:2
+19 ;
+20 ;Build segment array
+21 KILL SCFUT
+22 SET WORK=+$PIECE($GET(^SCPT(404.48,SCEVIEN,0)),U,8)
+23 IF WORK
NEW HLEID
SET HLEID=$$HLEIDW()
SET RESULT=$$BUILD^SCMCHLP(VARPTR,.HL,.XMITARRY,SCEVIEN)
+24 IF 'WORK
SET RESULT=$$BUILD^SCMCHLB(VARPTR,.HL,.XMITARRY)
+25 ;Error occurred when building segment array
IF +RESULT<0
Begin DoDot:3
+26 SET @XMITERR@(VARPTR)=$PIECE(RESULT,"^",2)
End DoDot:3
QUIT
+27 ;
+28 ;If in Review mode, display info and Quit.
+29 ;
IF MODE=2
Begin DoDot:3
+30 WRITE !,VARPTR_" "_$SELECT('$DATA(@XMITARRY):"No ",1:"")_"Data Found"
End DoDot:3
QUIT
+31 ;
+32 ;If no segments built, turn off transmission flag and Quit.
+33 IF '$DATA(@XMITARRY)
IF '$GET(SCFUT)
DO FLAG(VARPTR,SCEVIEN)
QUIT
+34 ;
+35 ;Generate message.
+36 ;
+37 ;^SCMCHLG Increments MSGCNT
IF '$$GENERATE^SCMCHLG()
QUIT
+38 ;Turn off transmission flag
IF '$GET(SCFUT)
DO FLAG(VARPTR,SCEVIEN)
+39 ;clean up variables
KILL @XMITARRY
End DoDot:2
+40 ;
+41 QUIT
End DoDot:1
+42 ;
+43 IF '$DATA(ZTQUEUED)
WRITE !,MSGCNT," messages sent."
+44 ;
+45 ;Send completion bulletin and clean up arrays.
+46 ;Don't do this if in DISPLAY mode.
IF MODE=1
Begin DoDot:1
+47 SET ERRCNT=$$COUNT^SCMCHLS(XMITERR)
+48 DO CMPLBULL^SCMCHLM(MSGCNT,ERRCNT,XMITERR)
+49 KILL @XMITARRY,@XMITERR
+50 KILL ^XTMP("SCMCHL")
End DoDot:1
+51 ;
+52 IF SCLIMIT<1
QUIT
+53 ;
+54 ;alb/rpm;Patch 224;Transmit "M"arked messages from Transmission Log
+55 DO EN^SCMCHLRR(.SCLIMIT)
+56 IF SCLIMIT<1
QUIT
+57 ;
+58 ;alb/rpm;Patch224;Transmit messages with overdue ACKnowledgment
+59 DO AUTO^SCMCHLRR(.SCLIMIT)
+60 QUIT
+61 ;
MANUAL ;User passed in a specific variable pointer value. This value will
+1 ;be used rather than $ORDERing thru "AACXMIT" xref.
+2 ;
+3 NEW SCMANUAL
+4 ;Indicates variable pointer was manually entered.
SET SCMANUAL=1
+5 ; A delete cannot be processed.
+6 ;
+7 ;Initialize array
+8 KILL @XMITARRY
+9 ;
+10 ;Build segment array
+11 IF $GET(WORK)
NEW HLEID
SET HLEID=$$HLEIDW()
SET RESULT=$$BUILD^SCMCHLP(VARPTR,.HL,.XMITARRY)
+12 IF '$GET(WORK)
SET RESULT=$$BUILD^SCMCHLB(VARPTR,.HL,.XMITARRY)
+13 ;Error occurred when building segment array
IF +RESULT<0
Begin DoDot:1
+14 SET @XMITERR@(VARPTR)=$PIECE(RESULT,"^",2)
End DoDot:1
QUIT
+15 WRITE !,VARPTR_" "_$SELECT('$DATA(@XMITARRY):"No ",1:"")_"Data Found",!
+16 ;
+17 ;Generate message - FOR TESTING PURPOSES ONLY!
+18 SET RESULT=$$GENERATE^SCMCHLG()
+19 KILL ^XTMP("SCMCHL")
+20 QUIT
+21 ;
FLAG(VARPTR,SCEVIEN) ;Turn off transmission flag. This removes event from "AACXMIT"
+1 ;xref in PCMM HL7 EVENT file.
+2 ;Input:
+3 ; VARPTR - Internal value of EVENT POINTER field
+4 ;
+5 IF $GET(VARPTR)']""
QUIT
+6 IF $GET(SCEVIEN)
DO TRANSMIT^SCMCHLE(SCEVIEN,0)
QUIT
+7 NEW IEN
+8 SET IEN=0
+9 ;
FOR
SET IEN=$ORDER(^SCPT(404.48,"AACXMIT",VARPTR,IEN))
IF 'IEN
QUIT
Begin DoDot:1
+10 DO TRANSMIT^SCMCHLE(IEN,0)
End DoDot:1
+11 QUIT
+12 ;
HLEIDW() ;Return workload sending event
+1 QUIT +$ORDER(^ORD(101,"B","SCMC SEND SERVER WORKLOAD",0))
HLEID() ;Return pointer to sending event
+1 IF $GET(WORK)
QUIT $$HLEIDW()
+2 QUIT +$ORDER(^ORD(101,"B","PCMM SEND SERVER FOR ADT-A08",0))
+3 QUIT