SD53P210 ;BP/CMF - Patch SD*5.3*210 utility routine; 02/17/2000
;;5.3;Scheduling;**210,1015**;AUG 13, 1993;Build 21
;
;
ENV ;Main entry point for Environment check point.
;
S XPDABORT=""
D PROGCHK(.XPDABORT) ;checks programmer variables
D PARMCHK(.XPDABORT) ;checks param file ien exists
I XPDABORT="" K XPDABORT
;
Q
;
;
PRE ;Main entry point for Pre-init
;
D PRE1 ;Delete PCMM HL7 ID file
D PRE2 ;Set HL7 Application name to PCMM
;
Q
;
;
POST ;Main entry point for Post-init
;
D POST1 ;Update c/s files
D POST2 ;Stuff 7 days into HL7 AUTO RETRANSMIT PERIOD field of the
; PCMM PARAMETER file
D POST3 ;Change HL7 Application Name
;
Q
;
;
;
PROGCHK(XPDABORT) ;checks for necessary programmer variables
;
I '$G(DUZ)!($G(DUZ(0))'="@")!('$G(DT))!($G(U)'="^") DO
.D BMES^XPDUTL("*****")
.D MES^XPDUTL("Your programming variables are not set up properly.")
.D MES^XPDUTL("Installation aborted.")
.D MES^XPDUTL("*****")
.S XPDABORT=2
.Q
Q
;
PARMCHK(XPDABORT) ;checks for proper param file ien
;
I '$D(^SCTM(404.44,1)) D
.D BMES^XPDUTL("*****")
.D MES^XPDUTL("Parameter file (#404.44) does not have proper IEN (1).")
.D MES^XPDUTL("Installation aborted.")
.D MES^XPDUTL("*****")
.S XPDABORT=2
.Q
Q
;
PRE1 ;Delete PCMM HL7 ID (#404.49) file, including data.
;rpm/alb - Added check for application version. If 210 has been loaded
; once then we don't want to initialize 404.49 with each TEST
; version install.
NEW DIU
I $$PATCH^XPDUTL("SD*5.3*210") D Q
. D BMES^XPDUTL("SD*5.3*210 previously installed. PCMM HL7 ID file not re-initialized.")
S DIU="^SCPT(404.49,"
S DIU(0)="DT"
D EN^DIU2
Q
;
PRE2 ;Set HL7 application name to PCMM
;rpm/alb A re-install of SD*5.3*210 resulted in the HL7 application name
; being blank in the PCMM SEND SERVER Protocol if the HL7
; application name was previously PCMM-210.
NEW DIC,DIE,DA,DR,X,Y
S DIC="^HL(771,"
S X="PCMM"
D ^DIC
I (Y<0) D Q
. D BMES^XPDUTL(" PCMM application not found")
I $$PATCH^XPDUTL("SD*5.3*210") D Q
. D BMES^XPDUTL("SD*5.3*210 previously installed. Setting HL7 application name to PCMM")
. S DIE=DIC
. S DA=+Y
. S DR=".01///PCMM"
. D ^DIE
. D MES^XPDUTL(" HL7 application name successfully changed to PCMM.")
Q
;
POST1 I $$UPCLNLST^SCMCUT("SD*5.3*210^NullClient^1^0^0") D Q
. D MES^XPDUTL("Client/Server files updated.")
. Q
D MES^XPDUTL("Client/Server files NOT updated.")
Q
;
POST2 ;Stuff 7 days into HL7 AUTO RETRANSMIT PERIOD field of the
;PCMM PARAMETER file
NEW SCERR,SCFDA
S SCFDA(404.44,"1,",16)=7
D FILE^DIE(,"SCFDA","SCERR")
Q
;
POST3 ;Change HL7 application name from PCMM to PCMM-210 in HL7 APPLICATION PARAMETER file. DBIA #3068: Approval from HL7 Package for this change.
;rpm/alb - removed eXact match since test sites may overlap 210 and 212.
; Application name needs to match the version installed.
N DIE,DIC,DA,DR,X,Y
D BMES^XPDUTL("Changing HL7 Application name from PCMM to PCMM-210")
S DIC="^HL(771,"
S X="PCMM"
D ^DIC
I (Y<0) D Q
.D BMES^XPDUTL(" PCMM application not found.")
I $P(Y,"^",2)="PCMM-210" D Q
.D MES^XPDUTL(" HL7 application name is PCMM-210. No change needed.")
S DIE=DIC
S DA=+Y
S DR=".01///PCMM-210"
D ^DIE
D MES^XPDUTL(" HL7 application name successfully changed to PCMM-210.")
Q
SD53P210 ;BP/CMF - Patch SD*5.3*210 utility routine; 02/17/2000
+1 ;;5.3;Scheduling;**210,1015**;AUG 13, 1993;Build 21
+2 ;
+3 ;
ENV ;Main entry point for Environment check point.
+1 ;
+2 SET XPDABORT=""
+3 ;checks programmer variables
DO PROGCHK(.XPDABORT)
+4 ;checks param file ien exists
DO PARMCHK(.XPDABORT)
+5 IF XPDABORT=""
KILL XPDABORT
+6 ;
+7 QUIT
+8 ;
+9 ;
PRE ;Main entry point for Pre-init
+1 ;
+2 ;Delete PCMM HL7 ID file
DO PRE1
+3 ;Set HL7 Application name to PCMM
DO PRE2
+4 ;
+5 QUIT
+6 ;
+7 ;
POST ;Main entry point for Post-init
+1 ;
+2 ;Update c/s files
DO POST1
+3 ;Stuff 7 days into HL7 AUTO RETRANSMIT PERIOD field of the
DO POST2
+4 ; PCMM PARAMETER file
+5 ;Change HL7 Application Name
DO POST3
+6 ;
+7 QUIT
+8 ;
+9 ;
+10 ;
PROGCHK(XPDABORT) ;checks for necessary programmer variables
+1 ;
+2 IF '$GET(DUZ)!($GET(DUZ(0))'="@")!('$GET(DT))!($GET(U)'="^")
Begin DoDot:1
+3 DO BMES^XPDUTL("*****")
+4 DO MES^XPDUTL("Your programming variables are not set up properly.")
+5 DO MES^XPDUTL("Installation aborted.")
+6 DO MES^XPDUTL("*****")
+7 SET XPDABORT=2
+8 QUIT
End DoDot:1
+9 QUIT
+10 ;
PARMCHK(XPDABORT) ;checks for proper param file ien
+1 ;
+2 IF '$DATA(^SCTM(404.44,1))
Begin DoDot:1
+3 DO BMES^XPDUTL("*****")
+4 DO MES^XPDUTL("Parameter file (#404.44) does not have proper IEN (1).")
+5 DO MES^XPDUTL("Installation aborted.")
+6 DO MES^XPDUTL("*****")
+7 SET XPDABORT=2
+8 QUIT
End DoDot:1
+9 QUIT
+10 ;
PRE1 ;Delete PCMM HL7 ID (#404.49) file, including data.
+1 ;rpm/alb - Added check for application version. If 210 has been loaded
+2 ; once then we don't want to initialize 404.49 with each TEST
+3 ; version install.
+4 NEW DIU
+5 IF $$PATCH^XPDUTL("SD*5.3*210")
Begin DoDot:1
+6 DO BMES^XPDUTL("SD*5.3*210 previously installed. PCMM HL7 ID file not re-initialized.")
End DoDot:1
QUIT
+7 SET DIU="^SCPT(404.49,"
+8 SET DIU(0)="DT"
+9 DO EN^DIU2
+10 QUIT
+11 ;
PRE2 ;Set HL7 application name to PCMM
+1 ;rpm/alb A re-install of SD*5.3*210 resulted in the HL7 application name
+2 ; being blank in the PCMM SEND SERVER Protocol if the HL7
+3 ; application name was previously PCMM-210.
+4 NEW DIC,DIE,DA,DR,X,Y
+5 SET DIC="^HL(771,"
+6 SET X="PCMM"
+7 DO ^DIC
+8 IF (Y<0)
Begin DoDot:1
+9 DO BMES^XPDUTL(" PCMM application not found")
End DoDot:1
QUIT
+10 IF $$PATCH^XPDUTL("SD*5.3*210")
Begin DoDot:1
+11 DO BMES^XPDUTL("SD*5.3*210 previously installed. Setting HL7 application name to PCMM")
+12 SET DIE=DIC
+13 SET DA=+Y
+14 SET DR=".01///PCMM"
+15 DO ^DIE
+16 DO MES^XPDUTL(" HL7 application name successfully changed to PCMM.")
End DoDot:1
QUIT
+17 QUIT
+18 ;
POST1 IF $$UPCLNLST^SCMCUT("SD*5.3*210^NullClient^1^0^0")
Begin DoDot:1
+1 DO MES^XPDUTL("Client/Server files updated.")
+2 QUIT
End DoDot:1
QUIT
+3 DO MES^XPDUTL("Client/Server files NOT updated.")
+4 QUIT
+5 ;
POST2 ;Stuff 7 days into HL7 AUTO RETRANSMIT PERIOD field of the
+1 ;PCMM PARAMETER file
+2 NEW SCERR,SCFDA
+3 SET SCFDA(404.44,"1,",16)=7
+4 DO FILE^DIE(,"SCFDA","SCERR")
+5 QUIT
+6 ;
POST3 ;Change HL7 application name from PCMM to PCMM-210 in HL7 APPLICATION PARAMETER file. DBIA #3068: Approval from HL7 Package for this change.
+1 ;rpm/alb - removed eXact match since test sites may overlap 210 and 212.
+2 ; Application name needs to match the version installed.
+3 NEW DIE,DIC,DA,DR,X,Y
+4 DO BMES^XPDUTL("Changing HL7 Application name from PCMM to PCMM-210")
+5 SET DIC="^HL(771,"
+6 SET X="PCMM"
+7 DO ^DIC
+8 IF (Y<0)
Begin DoDot:1
+9 DO BMES^XPDUTL(" PCMM application not found.")
End DoDot:1
QUIT
+10 IF $PIECE(Y,"^",2)="PCMM-210"
Begin DoDot:1
+11 DO MES^XPDUTL(" HL7 application name is PCMM-210. No change needed.")
End DoDot:1
QUIT
+12 SET DIE=DIC
+13 SET DA=+Y
+14 SET DR=".01///PCMM-210"
+15 DO ^DIE
+16 DO MES^XPDUTL(" HL7 application name successfully changed to PCMM-210.")
+17 QUIT