Home   Package List   Routine Alphabetical List   Global Alphabetical List   FileMan Files List   FileMan Sub-Files List   Package Component Lists   Package-Namespace Mapping  
Info |  Desc |  Directly Accessed By Routines |  Accessed By FileMan Db Calls |  Pointed To By FileMan Files |  Pointer To FileMan Files |  Fields |  External References |  Global Variables Directly Accessed |  Local Variables |  All
Print Page as PDF
Global: ^RA(79

Package: Radiology Nuclear Medicine

Global: ^RA(79


Information

FileMan FileNo FileMan Filename Package
79 RAD/NUC MED DIVISION Radiology Nuclear Medicine

Description

Directly Accessed By Routines, Total: 73

Package Total Routines
Radiology Nuclear Medicine 69 HL7 RECEIVING APPLICATIONS    IMAGING LOCATIONS    PERF INDIC SMTP E-MAIL ADDRESS    RA63PST    RACDR    RACNLU    RACTOE    RACTOE4
RACTRG2    RACTVR    RACTWR    RADLQ1    RADLY1    RAFLH2    RAFLM1    RAHLO
RAHLO3    RAHLQ    RAHLROUT    RAHLRU1    RAIPRE2    RAIPST1    RALWKL    RAMIS
RAMIS2    RANMED1    RANMUSE2    RAO7PC1    RAO7PC1A    RAO7PC3    RAO7UTL1    RAORD1
RAORD2    RAORD5    RAORD8    RAORDQ    RAORDU    RAORR1    RAPM2    RAPM3
RAPRC    RAPRI    RAPROD    RAPSET    RAPTLU    RAREG    RAREG2    RAREG3
RARIC    RARIC1    RARTR2    RARTST    RARTST2A    RASTREQ    RASTREQN    RASYS
RATRAN    RAUTL0    RAUTL2    RAUTL4    RAUTL5    RAUTL6    RAUTL7    RAUTL8
RAWFR2    RAWKL1    REGISTERED EXAMS    USER PREFERS LONG DISPLAY    ^RA(79    
IHS Mods To Radiology Nuclear Medicine 4 BRAPRAD    BRARPT1    BRARPT3    BRARPT5    

Accessed By FileMan Db Calls, Total: 5

Package Total Routines
Radiology Nuclear Medicine 5 RA2IPST    RAMAGU13    RAO7MFN    RAPM3    RASYS    

Pointed To By FileMan Files, Total: 2

Package Total FileMan Files
Radiology Nuclear Medicine 2 IMAGING LOCATIONS(#79.1)[25]    RAD/NUC MED PATIENT(#70)[#70.02(3)]    

Pointer To FileMan Files, Total: 5

Package Total FileMan Files
Kernel 3 DEVICE(#3.5)[100]    INSTITUTION(#4)[.01]    NEW PERSON(#200)[#79.03(.01)]    
Health Level Seven 1 HL7 APPLICATION PARAMETER(#771)[#79.02(.01)]    
Radiology Nuclear Medicine 1 IMAGING LOCATIONS(#79.1)[#79.01(.01)]    

Fields, Total: 36

Field # Name Loc Type Details
.01 DIVISION 0;1 POINTER TO INSTITUTION FILE (#4)
************************REQUIRED FIELD************************
INSTITUTION(#4)

  • INPUT TRANSFORM:  S DINUM=X
  • LAST EDITED:  NOV 07, 1994
  • HELP-PROMPT:  Enter the name of the division.
  • DESCRIPTION:  
    This field contains the name of this division.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
    UNEDITABLE
  • NOTES:  XXXX--CAN'T BE ALTERED EXCEPT BY PROGRAMMER
  • CROSS-REFERENCE:  79^B
    1)= S ^RA(79,"B",$E(X,1,30),DA)=""
    2)= K ^RA(79,"B",$E(X,1,30),DA)
    Regular 'B' cross reference assigned by FileMan.  DINUM'ed with the Institution file (4).
.11 TRACK EXAM STATUS CHANGES .1;10 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es to track exam status changes.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' to collect the date and the time of exam status changes.  If the data is collected, it is stored with the case in the Activity Log subfile of the Rad/Nuc Med Patient file.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.111 ASK EXAM STATUS TIME .1;11 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es is you want the user asked the time of the status change.
  • DESCRIPTION:  This 'division' parameter is used if the 'Track Exam Status Changes' parameter is set to 'Yes'. This parameter may be set to 'Yes' to indicate that the user should be asked the time of the status change. If this parameter
    is set to 'No', then the system automatically uses the current date and time.
    (If exam data is entered significantly later than the patient is actually processed, then this parameter could be set to 'Yes' so that the user can put in the actual time the work was done.)
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.112 ALLOW STANDARD REPORTS .1;12 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if you want the transcriptionist to be able to select a standard report.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' if the transcriptionist should be given the opportunity to select a standard report during the report entry/edit process.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.113 ALLOW BATCHING OF REPORTS .1;13 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if the transcriptionist should be allowed to batch reports.
  • DESCRIPTION:  This 'division' parameter can be set to 'Yes' if the transcriptionist should be given the opportunity to place reports in a batch during report entry.
    Batching of reports has the following advantages:
    1)  Reports can be re-printed easily
    2)  Two or more users are allowed to use the same
    report printer without interweaving of reports
    3)  Allows for batch verifying of reports
    4)  Provides a mechanism for logical grouping of reports
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.114 ALLOW COPYING OF REPORTS .1;14 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if the transcriptionist should be able to copy the contents of one report into another.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' if the transcriptionist should be given the opportunity to copy the contents of one report into another.  The report text and impression will be copied.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.115 ALLOW 'RELEASED/UNVERIFIED' .1;15 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if 'Released/Unverified' reports should be allowed.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' to allow reports to have the status 'RELEASED/UNVERIFIED' which permits the displaying of the report to users outside of the Imaging service even if it is unverified.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.116 IMPRESSION REQUIRED ON REPORTS .1;16 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if an impression is required.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' to indicate that an impression is required to be given on a report before:  1) the report can be verified and  2) the exam can be considered 'complete'.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.117 ASK 'REQUESTED DATE' .1;17 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if the transcriptionist should be prompted for the desired date.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' if the transcriptionist should be prompted for the Desired Date for the exam.
  • TECHNICAL DESCR:  
    This field is set to 'YES' by the system.  The ADPAC never edits it.  It is not asked in the Division Parameter Set-up option.  Instead, the edit template for the set-up stuffs 'YES' in the field.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.118 ALLOW VERIFYING BY RESIDENTS .1;18 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if interpreting residents should be allowed to verify other interpreting physicians' reports.
  • DESCRIPTION:  This 'division' parameter can be set to 'Yes' to allow interpreting residents to verify other interpreting physicians' reports while using the 'On-line Verifying of Reports' option.
    If the parameter is set to 'Yes' then only those residents whose individual parameter (ALLOW VERIFYING OF OTHERS) in the 'New Person' file is also set to 'Yes' will be allowed to verify other interpreting physicians'
    reports.
    If this division parameter is set to 'No' then no residents will be allowed to verify other physicians' reports, regardless of how the individual parameter is set in the 'New Person' file.
.119 TRACK REQUEST STATUS CHANGES .1;19 SET
  • 'y' FOR YES;
  • 'n' FOR NO;

  • LAST EDITED:  JUN 26, 1988
  • HELP-PROMPT:  Enter 'Y'es if you want to track request status changes.
  • DESCRIPTION:  This 'division' parameter can be set 'Yes' to collect the date and the time of request status changes. If data is collected the new status, computer user, and, sometimes, the reason for the status change, are stored with
    the order in the Request Status Times subfile of the Rad/Nuc Med Orders file.
.12 PRINT FLASH CARD FOR EACH EXAM .1;2 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if you want a flash card printed for each exam (i.e. case).
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' if one flash card should be printed for each exam (i.e. case). If this parameter is set to 'Yes', then the 'location' parameter, 'How Many Flashcards Per Visit' is ignored.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.121 ASK 'IMAGING LOCATION' .1;21 SET
  • 'y' FOR YES;
  • 'n' FOR NO;

  • LAST EDITED:  JUL 12, 1995
  • HELP-PROMPT:  Enter 'y'es if the user should be asked for an imaging location when requesting an exam.
  • DESCRIPTION:  This division 'parameter' can be set to 'Yes' to indicate that the user should be asked when requesting an exam, which 'Imaging Location' the request should be forwarded to. It is recommended that this field be set to
    'Yes' to facilitate sorting of requests by imaging location for various reports.  Answering 'Yes' to this questions causes the 'SUBMIT REQUEST TO:' prompt to appear after a request is created.
  • CROSS-REFERENCE:  79^AC1^MUMPS
    1)= D:+$$ORVR^RAORDU()>2.5 PUT^XPAR(DA_";DIC(4,","RA SUBMIT PROMPT",1,$S(X="y":1,1:0))
    2)= Q
    3)= Do not delete!
    This cross-reference updates a mirror image parameter field in the OE/RR package.  OE/RR stores this parameter so they can determine if the 'SUBMIT REQUEST TO' question was asked for a particular division in the
    Radiology/Nuclear Medicine software.
.122 ALLOW RPTS ON CANCELLED CASES? .1;22 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  JAN 14, 1994
  • HELP-PROMPT:  Enter 'Y'es if a user without the RA MGR key can enter a report on a cancelled case.
  • DESCRIPTION:  
    This field will determine if a user who does not have the RA MGR key may enter a report for an exam that has a status of CANCELLED.
.124 TIME LIMIT FOR FUTURE EXAMS .1;24 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>168)!(X<0)!(X?.E1"."1N.N) X
  • LAST EDITED:  MAR 29, 1994
  • HELP-PROMPT:  Enter the number of hours in the future (0-168) that a user may register a patient for an exam.
  • DESCRIPTION:  
    This is the maximum number of hours in the future that a user may register a patient for an exam.  If this prompt is bypassed, the user may not register a patient at a future date.
  • TECHNICAL DESCR:  This data will be used as an upper limit when the user inputs the Exam Date. (.01 field of subfile 70.02 within file 70) This division parameter was added to allow sites to prevent future registration if they wish,
    as well as to set reasonable limits so that dates in the future are not entered in error.
.125 WARNING ON RPTS NOT YET VERIF? .1;25 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  SEP 18, 1996
  • HELP-PROMPT:  Enter 'yes' to get the report status printed on unverified reports.
  • DESCRIPTION:  If this field is set to 'Yes' results reports in any status except 'Verified' will print the status surrounded by asterisks under the body of the report. If this field is set to 'No' or left unanswered, the status box
    will not print on reports not yet verified.  This can be used to make sure that hardcopies of unverified results reports are not accidentally placed in patient charts or interpreted as the final results.
.126 AUTO E-MAIL TO REQ. PHYS? .1;26 SET
  • '1' FOR yes;

  • LAST EDITED:  JAN 29, 1996
  • HELP-PROMPT:  Enter 'Y'es to automatically send Requesting Physicians the radiology reports via e-mail.
  • DESCRIPTION:  Entering 'Y'es will turn on a feature that automatically sends the Radiology/Nuclear Medicine findings report to the Requesting Physician via e-mail at the time it is verified. If this field is left blank, verified
    reports will not be e-mailed to the requesting physician.
.127 ALLOW E-SIG ON COTS HL7 RPTS .1;27 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  OCT 01, 1999
  • HELP-PROMPT:  Enter 'Y' to allow VISTA e-sig on COTS reports.
  • DESCRIPTION:  Entering 'Y' will turn on a feature that automatically adds the Electronic Signature Block printed name of the Verifying Physician that signed the report being transmitted to Rad/Nuc Med via an HL7 interface to a COTS
    voice reporting system.  This parameter is only checked for COTS HL7 interfaces that use the Generate/Process Routine 'RAHLTCPB' in the subscriber protocol.
.128 INTERPRETING STAFF REQ'D? .1;28 SET
  • 'Y' FOR YES;
  • 'N' FOR NO;

  • LAST EDITED:  DEC 27, 1999
  • HELP-PROMPT:  Is Interpreting Staff Required for this Divison?
  • DESCRIPTION:  
    This field should be set to YES if you require entry of 'PRIMARY INTERPRETING STAFF' (file 70, field #15) to be mandatory for this division when entering Diagnostic data or Reports.
.129 HL7 RECEIVING APPLICATIONS HL7;0 POINTER Multiple #79.02 79.02

  • DESCRIPTION:  
    This field holds a list of pointers to the HL7 APPLICATIONS file (#771).
.131 USE SITE ACCESSION NUMBER? .1;31 SET
  • 'Y' FOR YES;
  • 'N' FOR NO;

  • LAST EDITED:  SEP 16, 2008
  • HELP-PROMPT:  Set this field to YES only when all devices are able to handle Site Specific Accession Numbers.
  • DESCRIPTION:  This parameter will function as a switch to turn on the use of the Site Specific Accession Number. Until this field is set to YES the system will NOT use the Site Specific Accession Number during registration of a new
    case.  Only when all devices are able to handle the Site Specific Accession Number should this field be set to YES, at which point the system will use the Site Specific Accession Number.
.16 AUTO USER CODE FILING .1;6 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es if you don't want users asked for their codes when processing exams.
  • DESCRIPTION:  This 'division' parameter can be set to indicate that the user should be asked for their access code during the processing of exams and reports of which various activity logs are kept. If this parameter is set to 'Yes',
    then the system automatically uses the user code associated with the initial logon.  If this parameter is set to 'No', then the system asks the access code during each process.
  • TECHNICAL DESCR:  
    This field is becoming obsolete.  It was used with PDP's before the existence of virtual terminals.  This field should normally be set to 'YES'.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.17 DETAILED PROCEDURE REQUIRED .1;7 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  DEC 22, 1994
  • HELP-PROMPT:  Enter 'Y'es if a 'detailed', 'parent' or 'series' exam is required during initial exam request/registration.
  • DESCRIPTION:  This 'division' parameter can be set to 'Yes' if the entry of a 'detailed', 'series' or 'parent' procedure type should be required during the initial exam registration or request.
    If this parameter is set to 'No', then the user can enter 'broad' procedure type, but this must be changed to 'detailed' or 'series' before the exam status can be changed to 'complete'.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
  • CROSS-REFERENCE:  79^AC^MUMPS
    1)= D:+$$ORVR^RAORDU()>2.5 PUT^XPAR(DA_";DIC(4,","RA REQUIRE DETAILED",1,$S(X="Y":1,1:0))
    2)= Q
    3)= Do not delete.
    This cross-reference updates a mirror image parameter field in the OE/RR package.  OE/RR stores this parameter so that they can determine whether to allow 'Broad' type procedures to be ordered at a given division.
.18 PRINT JACKET LBLS W/EACH VISIT .1;8 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  FEB 25, 1991
  • HELP-PROMPT:  Enter 'Y'es to print jacket labels with each visit.
  • DESCRIPTION:  This 'division' parameter can be set to 'Yes' to indicate that a jacket label should be printed automatically during each visit.
    If this field is set to YES and the field 'HOW MANY JACKET LABELS PER VISIT' in the IMAGING LOCATIONS (79.1) file is set to zero, then the default will become two (i.e., two jacket labels will print out).
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
.19 ASK 'CAMERA/EQUIP/RM' .1;9 SET
  • 'Y' FOR yes;
  • 'N' FOR no;

  • LAST EDITED:  JUN 03, 1994
  • HELP-PROMPT:  Enter 'Y'es if user should be asked for camera/equip/rm when editing an exam.
  • DESCRIPTION:  
    This 'division' parameter can be set to 'Yes' to indicate that the 'camera/equip/rm' should be asked during exam editing.
    SOURCE OF DATA:   COORDINATOR
25 CONTRAST REACTION MESSAGE CON;1 FREE TEXT

  • INPUT TRANSFORM:  K:$L(X)>70!($L(X)<5) X
  • LAST EDITED:  NOV 29, 1984
  • HELP-PROMPT:  Enter a warning message, between 5 and 70 characters in length, to be displayed for patients who have had a reaction to contrast medium.
  • DESCRIPTION:  This is an optional field that may contain a site-defined message to be displayed with the warning message for patients who have had a reaction to the contrast medium. For example, it may contain a reminder to use a
    yellow sticker for this patient's films.
    This field is only used for exams which may involve the use of contrast medium.  The message must be 5-70 characters in length.
    SOURCE OF DATA:   RAD/NUC MED COORDINATOR
50 IMAGING LOCATIONS L;0 POINTER Multiple #79.01 79.01

  • LAST EDITED:  JUN 08, 1994
  • DESCRIPTION:  
    This field points to file #79.1 to indicate the name of the Imaging location associated with this division.  A location may be associated with only one division.
75 CLINICAL HISTORY MESSAGE HIS;1 FREE TEXT

  • INPUT TRANSFORM:  K:$L(X)>70!($L(X)<5) X
  • LAST EDITED:  DEC 24, 1987
  • HELP-PROMPT:  Enter a warning message, between 5 and 70 characters in length, to be displayed prior to prompting for clinical history when requesting an exam.
  • DESCRIPTION:  This is an optional field that may contain a site-defined message to be displayed with a warning message which will be displayed in order entry, immediately proceeding the clinical history prompt. The message must be 5-70
    characters in length.
100 RESOURCE DEVICE RDEV;1 POINTER TO DEVICE FILE (#3.5) DEVICE(#3.5)

  • INPUT TRANSFORM:  S DIC("S")="I $P(^(""TYPE""),""^"")=""RES""" D ^DIC K DIC S DIC=DIE,X=+Y K:Y<0 X
  • LAST EDITED:  NOV 01, 1996
  • HELP-PROMPT:  Enter the Resource Device for this division.
  • DESCRIPTION:  A Resource device may be entered here if the facility wishes to control the rate at which tasked exam status updates are released to be processed. This is advised if the facility is experiencing drastic system slowdowns
    due to periodic heavy use of the online report verification and batch verification of reports options, which can queue a large number of tasks at once.  However, if the facility chooses to enter a Resource Device in this
    field, IRM should be careful to completely follow all directions in Kernel documentation after a system crash to bring this Resource Device back up.  Failure to follow those directions could result in Rad/Nuc Med tasks
    being severely delayed, and data corruption.
  • SCREEN:  S DIC("S")="I $P(^(""TYPE""),""^"")=""RES"""
  • EXPLANATION:  Only devices whose TYPE is 'Resource' may be selected.
125 RPHARM DOSE WARNING MESSAGE RWARN;0 WORD-PROCESSING #79.0125

  • DESCRIPTION:  This field contains the message displayed to the user when the dose falls outside the range of the 'Low Adult Dose' and the 'High Adult Dose' fields. These fields reside in the Default Radiopharmaceuticals multiple in the
    Rad/Nuc Med Procedures file.  Use the 'Procedure Enter/Edit' option to adjust these values.
130 ASK PCC DATE/TIME .1;30 SET
  • 'Y' FOR YES;
  • 'N' FOR NO;

  • LAST EDITED:  MAR 22, 1994
  • HELP-PROMPT:  A "YES" answer to this parameter will cause PCC Date/Time to be asked and required during the request process. The PCC Date/Time will be carried over to the exam and to the report.
150 USER PREFERS LONG DISPLAY LDIS;0 POINTER Multiple #79.03 79.03

  • LAST EDITED:  JUL 16, 2002
175 PERF INDIC SMTP E-MAIL ADDRESS 1;0 Multiple #79.0175 79.0175

  • LAST EDITED:  AUG 08, 2003
9999999.1 SEND PCC AT EXAMINED 9999999;1 SET
  • '0' FOR NO;
  • '1' FOR YES;

  • LAST EDITED:  AUG 18, 1999
  • HELP-PROMPT:  This prompt determines whether exam date will be sent to PCC when an exam reaches EXAMINED status. A response of YES will send exam date to PCC at EXAMINED only. No sends at VERIFIED only.
  • DESCRIPTION:  
    This prompt permits Radiology customers with the option to pass exam data to PCC when an exam reaches the EXAMINED status, or when a report is verified.
9999999.2 PREGNANCY DEFAULT TO UNKNOWN 9999999;2 SET
  • '0' FOR NO;
  • '1' FOR YES;

  • LAST EDITED:  AUG 17, 2011
  • HELP-PROMPT:  If you answer YES the pregnancy status will default to Unknown at the time of Registering a Patient, if the user does not enter a value.
9999999.3 PREGNANCY EDIT AT VERIFIED 9999999;3 SET
  • '0' FOR NO;
  • '1' FOR YES;

  • LAST EDITED:  AUG 17, 2011
  • HELP-PROMPT:  If you answer YES the pregnancy status may be edited after a report has been Verified. The Exam Status will not change to Complete unless a Pregancy Status has been entered.

External References

Name Field # of Occurrence
^DIC 100+1
$$ORVR^RAORDU .121(XREF 1S), .17(XREF 1S)
PUT^XPAR .121(XREF 1S), .17(XREF 1S)

Global Variables Directly Accessed

Name Line Occurrences  (* Changed,  ! Killed)
^RA(79 - [#79] .01(XREF 1S), .01(XREF 1K)

Local Variables

Legend:

>> Not killed explicitly
* Changed
! Killed
~ Newed

Name Field # of Occurrence
>> DA .01(XREF 1S), .01(XREF 1K), .121(XREF 1S), .17(XREF 1S)
DIC 100+1!*
DIC("S" 100+1*, 100SCR+1*
>> DIE 100+1
>> DINUM .01+1*
X .01+1, .01(XREF 1S), .01(XREF 1K), .121(XREF 1S), .124+1!, .17(XREF 1S), 25+1!, 75+1!, 100+1*!
>> Y 100+1
Info |  Desc |  Directly Accessed By Routines |  Accessed By FileMan Db Calls |  Pointed To By FileMan Files |  Pointer To FileMan Files |  Fields |  External References |  Global Variables Directly Accessed |  Local Variables |  All