Home   Package List   Routine Alphabetical List   Global Alphabetical List   FileMan Files List   FileMan Sub-Files List   Package Component Lists   Package-Namespace Mapping  
Info |  Details |  All
Print Page as PDF
Sub-Field: 700.017

Package: Medicine

PULMONARY FUNCTION TESTS(#700)-->700.017

Sub-Field: 700.017


Information

Parent File Name Number Package
PULMONARY FUNCTION TESTS(#700) VOLUME STUDY 700.017 Medicine

Details

Field # Name Loc Type Details
.01 VOLUME STUDY TYPE 0;1 SET
  • 'B' FOR BODY BOX;
  • 'I' FOR INERT GAS DILUTION;
  • 'N' FOR NITROGEN WASH OUT;
  • 'X' FOR X-RAY PLANIMETRY;

  • LAST EDITED:  SEP 12, 1991
  • HELP-PROMPT:  Enter the type of Lung Volume Study done.
  • DESCRIPTION:  
    This field identifies the type of Volume Study done.
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE:  UNKNOWN
  • CROSS-REFERENCE:  700.017^B
    1)= S ^MCAR(700,DA(1),3,"B",$E(X,1,30),DA)=""
    2)= K ^MCAR(700,DA(1),3,"B",$E(X,1,30),DA)
  • CROSS-REFERENCE:  700^AV^MUMPS
    1)= S ^MCAR(700,"AV",$P(^MCAR(700,DA(1),0),U,2),X,9999999.9999-$P(^MCAR(700,DA(1),0),U),DA(1),DA)=""
    2)= K ^MCAR(700,"AV",$P(^MCAR(700,DA(1),0),U,2),X,9999999.9999-$P(^MCAR(700,DA(1),0),U),DA(1),DA)
    This cross-reference indexes the date and time of the most recent volume study of this type for this pulmonary function test.
1 TLC 0;2 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>15.99)!(X<.05)!(X?.E1"."3N.N) X
  • LAST EDITED:  APR 10, 1990
  • HELP-PROMPT:  Enter the Total Lung Capacity (TLC) measured in Liters: .05-15.99
  • DESCRIPTION:  
    This field identifies the Total Lung Capacity measured.
  • TECHNICAL DESCR:  
    ORDER ENTRY TYPE:  UNKNOWN
2 VC 0;3 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>15.99)!(X<.05)!(X?.E1"."3N.N) X
  • HELP-PROMPT:  Enter the Vital Capacity (VC) measured in Liters: .05-15.99
  • DESCRIPTION:  
    This field identifies the measured Vital Capacity.
3 FRC 0;4 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>9.99)!(X<.05)!(X?.E1"."3N.N) X
  • LAST EDITED:  APR 10, 1990
  • HELP-PROMPT:  Enter the Functional Residual Capacity (FRC) measured in Liters: .05-9.99
  • DESCRIPTION:  
    This field identifies the measured Functional Residual Capacity.
4 RV 0;5 NUMBER

  • INPUT TRANSFORM:  K:+X'=X!(X>9.99)!(X<.05)!(X?.E1"."3N.N) X
  • HELP-PROMPT:  Enter the Residual Volume (RV) measured in Liters: .05-9.99
  • DESCRIPTION:  
    This field identifies the measured Residual Volume.
6 NOTES 0;6 FREE TEXT

  • INPUT TRANSFORM:  K:$L(X)>60!($L(X)<2) X
  • LAST EDITED:  APR 10, 1990
  • HELP-PROMPT:  Enter notes on this volume study: 2-60 characters
  • DESCRIPTION:  
    This field identifies a free text field for entering a note on the current Volume Study.
Info |  Details |  All